Air Conditioner Dehumidifier

YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP


YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP
YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP

YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP    YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP

YMGI 48000 BTU 4 TON. DUCTLESS MINI SPLIT AIR CONDITIONER. HEAT PUMP 4 X 9000+12000. THIS SYSTEM HAS BEEN CONFIGURED TO BE SUITABLE TO WORK IN A COMMERCIAL ENVIRONMENT WITH HIGH TRAFFIC SUCH AS SHOPS GARAGE RESTAURANT.

5 SETS OF LINE SETS INCLUDED AT 25 FT EACH! Condition : Brand New item unused unopened in original sealed package. Five Zone Air Condition with Heat Pump. One Outdoor unit with 5 Indoor units (4 X 9000 BTU, 12000 BTU) suitable for a commercial environment with high traffic.

48000 BTU 4 Ton Heating Cooling And Dehumidification. 21 SEER DC Inverter Compressor from Mitsubishi.

Super Quiet Auto Restart, digital Timer and Turbo Mode. 21 SEER efficiency, DC inverter technology. Whisper-quiet operation, Low voltage start. Stable Operation at Low Frequency. Random pitch cross flow fan wheel. LCD display, Turbo mode, 3 fan speeds. Quick access, washable air filter. Auto level swing, Wide angle air distribution, Auto Restart.

24-hour programmable timer, Sleep mode, Independent Dehumidification. Enhanced copper/coil, Corrosion resistant cabinet, Thoroughly tested ensure longer performance. Intelligent Auto-Defrosting: The unit can enter or quit the defrosting mode automatically by timely detecting the frosting situation of the outdoor unit. Sleep Mode: Because our body temperature cools down as we sleep, the unit automatically adjusts the setting for all-night comfort. Air Purifying and Deodorizing Filters: Industrial development has offered from one side a better life style, but on the other side, it has increased polluting substances presence in the air that helps in spreading of various kinds of diseases.

Among the polluting agents, the ones we can more frequently find at home are anti-bacterial dust particles, moulds and etc, which are causing allergic phenomenon, breathing and typical upper respiratory problems. This dual washable filter screen is effective in preventing anti-bacteria mould and duct particles and ensuring a healthy indoor environment. Turbo Mode: This function enables the unit to reach the preset temperature in the shortest time. Self-diagnosis and Auto-Protection Function: This function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode.

IMPORTANT NOTES ABOUT THE DC INVERTER SYSTEM VARIOUS PERFORMANCES. The rated performance data printed on the nameplate were tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up. Actually the DC inverter outdoor unit could modulate to match whatever capacity needs are called/requested from indoor side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number. Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes.

Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors. When the rated total capacity of all the indoor units exceeds the rated capacity of outdoor unit, each indoor unit may not output the rated capacity and one may differ from other, upon other installation/operation factors, it all units are turned on to run compressor simultaneously. Whenever the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" - 5/8 adaptor is to be used in between. This reducer is packed separately and shall be installed at job site. Any indoor unit is 30' or more apart from the outdoor unit, better to adjust refrigerant. If it is 50' or more apart, better to upper size the copper lines and adjust refrigerant. Any run cannot be more than 100' apart from the outdoor unit; otherwise, that indoor unit capacity may be reduced. BTU / Area Coverage Guide. 9000 BTU covers Approx 350 ft². 12000 BTU covers Approx 500 ft². 18000 BTU covers Approx 750 ft². 24000 BTU covers Approx 1100 ft².

Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation. YMGI does not provide installation for equipment. Customer will need to hire a licensed HVAC technician and install the equipment in a professional manner.

YMGI and Emma_bz cannot be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any refrigeration line by anyone not properly licensed. YMGI endeavour to ensure all information given here (include technical data, and other information) is correct. However due to omissions, errors and out-of-date data from constant improvement, YMGI and Emma_bz reserve all rights to modify any part of the content without notice. Every reasonable effort has been made to ensure all information contained here is correct.

The item "YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP" is in sale since Friday, February 21, 2020. This item is in the category "Home & Garden\Home Improvement\Heating, Cooling & Air\Central Heating & Cooling Systems\Ductless Mini Split Systems". The seller is "emma_bz" and is located in O'Fallon, Missouri.

This item can be shipped to United States.
  1. Indoor Set: 4 X 9000 BTU +12000 BTU
  2. Indoor Unit Type: Wall Mount
  3. Energy Star: Compliant
  4. Model: WMMS-48CH-V2B(59)4/09EW-09EW-09EW-09EW-12EW
  5. Compressor Type: MITSUBISHI DC Inverter
  6. Power Source: 208-230V / 1ph / 60Hz
  7. Coverage: Approx 2100Sq.ft (4 x 400+500)*
  8. Cooling BTU/Hr: Split System
  9. SEER: 21
  10. Cooling Capacity BTU: 48000 BTU
  11. Type: FIVE Zone Mini Split System
  12. Features: Low Ambient Operation
  13. Refrigerant: R410a Precharged
  14. MPN: WMMS-48CH-V2B(59)4/09EW-09EW-09EW-09EW-12EW
  15. Brand: YMGI
  16. Voltage: 208/230 V

YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP    YMGI 48000 BTU 4 Ton 5 ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP