Air Conditioner Dehumidifier

YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz


YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz

YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz    YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz
YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz. 24000 BTU + 24000 BTU.

DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP. 208-230V 21 SEER DC INVERTER.

If you require system at different capacity or style or you have any question. Important Notes : New or cleaned Filter for your indoor air Handler will effectively control your air quality for this flu season, Stay healthy! WE HAVE SYSTEM IN other capacity. PLEASE CHECK WITH US FOR YOUR CONFIGURATION. Condition : Brand New item unused unopened in original sealed package. This System is idea for Commercial space with high traffic area such as Office with open space, garage workshop, restaurant and cafe with kitchen area, shops and Bars etc. Two Zone Air Condition with Heat Pump. One Outdoor unit with 2 Indoor units (24000 BTU, 24000 BTU).

4 Tons Heating Cooling And Dehumidification. 21 SEER DC Inverter Compressor from Mitsubishi. Super Quite Auto Restart, digital Timer and Turbo Mode. 21 SEER efficiency, DC inverter technology.

Whisper-quiet operation, Low voltage start. Stable Operation at Low Frequency. Random pitch cross flow fan wheel. LCD display, Turbo mode, 3 fan speeds. Quick access, washable air filter. Auto level swing, Wide angle air distribution, Auto Restart. 24-hour programmable timer, Sleep mode, Independent Dehumidification. Enhanced copper/coil, Corrosion resistant cabinet, Thoroughly tested ensure longer performance. The unit can enter or quit the defrosting mode automatically by timely detecting the frosting situation of the outdoor unit. Because our body temperature cools down as we sleep, the unit automatically adjusts the setting for all-night comfort. Air Purifying and Deodorizing Filters. Industrial development has offered from one side a better life style, but on the other side, it has increased polluting substances presence in the air that helps in spreading of various kinds of diseases. Among the polluting agents, the ones we can more frequently find at home are anti-bacterial dust particles, moulds and etc, which are causing allergic phenomenon, breathing and typical upper respiratory problems. This dual washable filter screen is effective in preventing anti-bacteria mould and duct particles and ensuring a healthy indoor environment. This function enables the unit to reach the preset temperature in the shortest time. This function can electronically detect the errors and display the diagnosis by a series of flashing LEDs on the indoor unit. Then the unit will automatically switch to protection mode. IMPORTANT NOTES ABOUT THE DC INVERTER SYSTEM VARIOUS PERFORMANCES.

The rated performance data printed on the nameplate were tested per AHRI 210/240 standards at standard indoor & outdoor conditions and standard installation set-up. Actually the DC inverter outdoor unit could modulate to match whatever capacity needs are called/requested from indoor side, to produce a wide range of capacities, minimum could be about 15% of the rated number and maximum could be around 160% of the rated number.

Once the DC inverter system is installed, each indoor unit's output and so the outdoor unit performance will all vary over the operation period: soft starting, turbo quick cooling/heating, maintaining, defrosting, switching, and other condition changes. Actual performance varies upon many factors such as indoor and outdoor temperatures, inter-connecting pipe length/ bending, elevation difference between indoor and outdoor units, refrigerant charging level, vacuum level, leakage, air or moisture or contamination level, foreign substance left in the piping, indoor filter clean level, indoor and outdoor coil conditions, and other factors. When the rated total capacity of all the indoor units exceeds the rated capacity of outdoor unit, each indoor unit may not output the rated capacity and one may differ from other, upon other installation/operation factors, it all units are turned on to run compressor simultaneously. Whenever the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas pipe of 1/2" or 5/8", one 3/8" - 1/2" or 3/8" - 5/8 adapter is to be used in between. This reducer is packed separately and shall be installed at job site. Any indoor unit is 30' or more apart from the outdoor unit, better to adjust refrigerant. If it is 50' or more apart, better to upper size the copper lines and adjust refrigerant. Any run cannot be more than 100' apart from the outdoor unit; otherwise, that indoor unit capacity may be reduced.

BTU / Area Coverage Guide. 12000 BTU covers Approx 500 ft². 18000 BTU covers Approx 75. 24000 BTU covers Approx 1100. Cover area is a guide only, other factors should also take into consideration such as ceiling height, number of windows and wall material those affect insulation.

Condenser R410A pre-charged (outdoor unit). 2 X Air Handler w/wall bracket. 2 X Wireless Remote control.

2 X Installation kit at 25Ft for each indoor unit Insulated copper line set , control cable and misc. YMGI does not provide installation for equipment. Customer will need to hire a licensed HVAC technician and install the equipment in a professional manner.

YMGI and bizlander cannot be held liable for any damage that caused by improper installation. Please be advised that federal law prohibits opening any refrigeration line by anyone not properly licensed. YMGI endeavour to ensure all information given here (include technical data, and other information) is correct.

However due to omissions, errors and out-of-date data from constant improvement, YMGI and bizlander reserve all rights to modify any part of the content without notice. Every reasonable effort has been made to ensure all information contained here is correct.

Ductless Mini Split Air Conditioner 60000 BTU Heat Pump Ceiling 5 Zone System. Ductless Mini Split Air Conditioner 60000 BTU Heat Pump Ceiling 5 Zone Split ALK. Ductless Mini Split Air Conditioner 60000 BTU Heat Pump Ceiling 5 Zone Split. Ductless Mini Split Air Conditioner 60000 BTU Heat Pump Ceiling 5 Zone Split SAQ. The item "YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz" is in sale since Friday, March 18, 2016. This item is in the category "Home & Garden\Home Improvement\Heating, Cooling & Air\Central Heating & Cooling Systems\Ductless Mini Split Systems".

The seller is "bizlanderhvacsolar" and is located in Long Island City, New York. This item can be shipped to United States.

  1. Model: WMMS-48CH-V2B(59)4/24EW-24EW
  2. Style: mini Split
  3. Energy Star: Compliant
  4. Coverage: 2200 Sq.ft
  5. Power Supply: 208-230V / 1ph / 60Hz
  6. Cooling BTU/Hr: 48000 BTU
  7. SEER: 21
  8. Power Source: 208-230V/1Ph/60Hz
  9. Type: Dual Zone Split System
  10. Features: Dual Zone
  11. Refrigerant: R410a Precharged
  12. MPN: WMMS-48CH-V2B(59)4/24EW-24EW
  13. Mounting Location: Wall
  14. Brand: YMGI
  15. Compressor Type: Mitsubishi DC Inverter
  16. Voltage: 208-230V/1Ph/60Hz


YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz    YMGI 48000 BTU DUAL ZONE DUCTLESS MINI SPLIT AIR CONDITIONER HEAT PUMP Biz